ÉCRU Decarboxylator: How to Use, Presets and Manual
The printed manual, in a form you can search. This page covers both canister models sold here - the Herb Decarboxylator Green 2oz and the 2 in 1 Decarboxylator & Infuser 3oz - with the preset cycles, the button-by-button procedure, the temperature charts both manuals print, and the safety terms they carry. Every figure below is quoted from the manual that ships in the box.
Which model do you have?
The two units differ in what they can do, so the procedure below splits by model. The model number is printed on the rating plate under the unit and on the box.
Herb Decarboxylator Green 2oz (ECRU-IF-01)
2 oz dry / 10 oz liquid · 3 preset heat cycles
$86.99View product2 in 1 Decarboxylator & Infuser 3oz (ECRU-IF-02)
3 oz dry / 20 oz liquid · Independent Decarb and Infuse modes
$106.99View product
Setting up: the six steps the Green 2oz and 2 in 1 share
Set it down. Place the unit on a flat, stable surface.
Fill the canister. Add ingredients to the canister as needed. Pack loosely, leaving room at the top.
Odor-reduction lid. Install the Odor-Reduction Lid onto the aluminum canister.
Cover lid. Install the Cover Lid securely.
Lock it. Lock the Airtight Lock.
Power. Plug the power cord into an outlet.

Herb Decarboxylator Green 2oz (ECRU-IF-01)
The Green 2oz decarbs and infuses from three preset heat cycles. Press MODE to move through them; the label under each one on the device is what the manual prints.
| Preset | Labelled | Temperature | Time |
|---|---|---|---|
| MODE 1 | CBD potent | 203°F | 60 min |
| MODE 2 | T*C potent | 230°F | 30 min |
| MODE 3 | T*C potent | 266°F | 35 min |

Running a decarb cycle
Load the canister. Fill the canister with herbs. Pack loosely, leaving room at the top.
Prepare the canister. Place the inner canister back into the decarboxylator and secure the Odor-Reduction Lid firmly onto the aluminum canister.
Secure the cover. Put the Cover Lid on the aluminum canister and lock the activator.
Power the unit. Plug in the unit to power it on.
Set time and temperature. Press ON/OFF MODE to select the desired mode, then use TMP/TME to adjust the time and temperature.
Start the cycle. The decarb cycle begins automatically 10 seconds after you select a mode.
Watch the pre-heat light. During pre-heating, the TMP indicator light glows green.
Countdown. Once pre-heating is complete, the countdown begins automatically.
Completion alert. When the process is complete, the unit beeps five times.
If you must open the decarboxylator before it has cooled, use heatproof gloves. Carefully remove the silicone lid, but do not touch the canister - it will be hot.
What the controls do
- LCD Screen - displays the current settings, time, and temperature.
- On/Off & Switch Modes - turns the device on or off and cycles through the three preset modes.
- Switch Time/Temperature - toggles between adjusting the time and adjusting the temperature.
- Up and Down Buttons - precise adjustment of the time and temperature setting.
- Odor-Reduction Lid - an additional seal that prevents spills and holds conditions inside the canister.
- Non-stick Canister - aluminum for heat transmission, coated with FDA-compliant non-stick material.
- Insulated Shell - holds internal temperature but may become hot during operation.
- Airtight Lock - locks the cover lid down for a sealed cycle.
How the cycle behaves
- Plugging the unit in flashes the LCD screen and indicator light for one second, then they turn off. Press ON/OFF to turn the device on; press and hold ON/OFF to turn it off.
- Once the device is on, press MODE to cycle through the three preset modes.
- During pre-heating the TMP indicator light glows green.
- To adjust time or temperature yourself instead of using a preset, wait for the TMP light to flash green and use ▲ or ▼ for temperature, or wait for the TME light to flash green and use ▲ or ▼ for time.
- To stop the unit at any time, press and hold ON/OFF MODE for three seconds to reset.
2 in 1 Decarboxylator & Infuser 3oz (ECRU-IF-02)
The 2 in 1 has no preset cycles. Instead it has a Decarb key and an Infuse key, and you set the time and temperature for each yourself from the guide below. It holds 3 oz of dry material and 20 oz of liquid, so a full butter or oil batch fits in one canister.

Running a decarb cycle
Load the canister. Load the canister with loose herb, leaving some space at the top.
Respect the capacity. Do not exceed 3 oz of dry material - the rated capacity of this canister.
Seal it. Place the canister in the decarboxylator and seal it with the silicone lid.
Start. Plug in the unit and press Decarb.
Set time and temperature. Adjust the time and temperature using the Time+/- and Temp+/- buttons.
Wait 10 seconds. The cycle starts automatically after 10 seconds.
Cool before handling. Allow the unit to cool down completely before handling the canister.
Stopping early. If needed, press Stop to stop the unit.
Running an infusion cycle
Load. Place your decarbed herb and the oil material of your choice into the aluminum canister.
Seal. Firmly place the silicone lid onto the aluminum canister, then place the cover lid on the canister and lock it securely.
Set and start. Set the time and temperature from the chart below, then wait 10 seconds for the infusion cycle to start.
| Carrier | Temp. °F | Temp. °C | Time |
|---|---|---|---|
| Vegetable glycerin | 120°F | 50°C | 3.5 hours |
| Olive oil (EVOO) | 165°F | 75°C | 2 hours |
| MCT oil | 165°F | 75°C | 2.5 hours |
| Sesame oil | 165°F | 75°C | 2.5 hours |
| Avocado oil | 175°F | 80°C | 2 hours |
| Coconut oil | 175°F | 80°C | 2 hours |
| Peanut oil | 175°F | 80°C | 2 hours |
The chart stops at oils and glycerin. Both manuals rate the canister at five sticks of butter, but neither prints a butter temperature, so there is no row for it here rather than a number we made up. For cannabutter specifically, the machine method is covered in Cannabutter Recipe: The Machine Method.
What the controls do
- LCD Screen - displays the current settings, time, and temperature, with Preheat, Decarb and Infuse indicators.
- Decarb / Infuse - separate keys for the two processes; press one to select that cycle.
- Temp+ / Temp- - adjusts the temperature.
- Time+ / Time- - adjusts the time.
- Start/Stop - powers the unit on and starts or stops a cycle.
- Cancel - clears the current selection.
- Non-stick Canister - aluminum for heat transmission, coated with FDA-compliant non-stick material.
- Silicone Lid and Cover Lid - seal the canister; the Airtight Lock holds the cover down.
How the cycle behaves
- To turn the unit on, plug it in and press Start/Stop. The LCD screen and light illuminate.
- Press Decarb to begin decarboxylation, or Infuse to start the infusion process.
- Press Temp+ or Temp- to adjust temperature, and Time+ or Time- to adjust time.
Decarb temperature guide
Printed identically in both manuals, and reproduced here as printed. This is material-level guidance rather than a device preset: the Green 2oz's three presets cover the first two rows, and on the 2 in 1 you dial these in by hand.
| Compounds | Temperature | Time | Effects listed in the manual |
|---|---|---|---|
| CBDA → CBD | 203°F (95°C) | 60 min | Anti-proliferative; anti-inflammatory |
| T*CA → T*C | 230°F - 266°F (110 - 130°C) | 30 - 35 min | Pain relief; appetite stimulation; anti-nausea; anti-inflammatory |
| CBGA → CBG | 220°F - 240°F (104 - 116°C) | 60 min | Anti-inflammatory; antibacterial; neuroprotective |
| CBNA → CBN | 240°F (116°C) | 30 - 40 min | Anti-spasmodic; anti-insomnia; analgesic |
Both manuals carry the same warning above this table: keep the herb completely dry, or the lid can open during decarboxylation.
The effect descriptions in the last column are reproduced from the manufacturer's manual. They are not medical advice, have not been evaluated by the FDA, and are not a promise of any outcome. Cannabis affects people differently, and the law varies by state and country.
What happens during a cycle
- The countdown does not start when you press start - it starts once the chamber actually reaches the set temperature. Pre-heating time is on top of the cycle time.
- Both models wait 10 seconds after you select a cycle before heating begins.
- Both beep five times when the process completes.
- Both have an auto-shutoff to prevent overheating.
Care and cleaning
- Unplug the unit from the power source before servicing or cleaning it.
- The canister lifts out of the housing, and both lids come off it, so you are not cleaning around the heating element.
- The canister is aluminium with an FDA-compliant non-stick coating, and the manual's own instruction before an infusion cycle is to ensure all components are clean and properly assembled.
- Neither manual documents a cleaning or storage procedure beyond that. For a specific spill, residue or odour question, contact support and we will answer for your model rather than guess.
Contact ÉCRU support for anything this page does not cover.
Important safeguards
Quoted from the manual, because these are the manufacturer's own safety terms rather than our summary of them.
- Read all instructions before operating this appliance and keep this manual for future reference.
- Check for damaged parts before use. Do not use the unit if any parts are damaged or are not working as expected.
- Always disconnect the unit from the power source before servicing or cleaning it. Unplug it when not in use, and do not plug it into a damaged outlet.
- This product is designed for indoor household use only. It is not a commercial-use product.
- This unit gets hot while in use. Use caution while handling it.
- Always pick the unit up by its side handles. Never pick it up by the top handle on the lid.
- Always use this unit in well-ventilated areas.
- Keep it out of the reach of children and never leave the device unattended.
- Do not operate outdoors or near any flammable or combustible materials, and do not use it during electrical storms.
- Monitor the product while it is in use. Do not leave it unattended when plugged into an outlet or powered on.
- To prevent electric shock and damage, do not immerse the unit in water.
- Do not unplug the unit by pulling on the cord, and never unplug it with wet hands.
- Always use 110/120-volt power sources. Do not use power converters (210/220 V).
- Do not operate under the influence of alcohol or drugs.
- Any alteration of this unit's components, substitution of other manufacturers' components, or repairs not carried out or authorised by ÉCRU will immediately void the warranty.
Frequently asked questions
- How do I use the ÉCRU decarboxylator?
- Load the canister loosely, leaving room at the top, seal it with the silicone lid and then the cover lid, and lock the airtight lock. Plug the unit in, select a cycle, and wait: the Green 2oz and the 2 in 1 both begin heating 10 seconds after you choose a cycle. The countdown starts only once the chamber reaches the set temperature, so pre-heating sits on top of the cycle time. When it finishes the unit beeps five times.
- Is ECRU the same brand as ÉCRU?
- Yes, and you will see it written both ways. ÉCRU is a US registered trademark, and the accent is part of the name, but listings, forum posts and reviews very often drop it. Same devices, same company, same warranty - if you are looking for an ECRU decarboxylator manual, this page is it.
- What temperature and time should I decarb at?
- Both manuals print the same guide: CBDA to CBD at 203°F for 60 minutes, T*CA to T*C at 230-266°F for 30-35 minutes, CBGA to CBG at 220-240°F for 60 minutes, and CBNA to CBN at 240°F for 30-40 minutes. The Green 2oz covers the first two with its three presets; the 2 in 1 has no compound presets, so you set these from the buttons.
- Which preset should I use on the Green 2oz?
- MODE 1 is labelled CBD potent and runs 203°F for 60 minutes. MODE 2 and MODE 3 are both labelled T*C potent: MODE 2 runs 230°F for 30 minutes and MODE 3 runs 266°F for 35 minutes. MODE 2 is the shorter, gentler of the two; MODE 3 pushes the same conversion harder.
- Can I set my own time and temperature?
- Yes, on both models. On the Green 2oz, wait for the TMP light to flash green and use the up and down buttons for temperature, or the TME light for time. On the 2 in 1, press Temp+ or Temp- for temperature and Time+ or Time- for time. Neither manual publishes a usable range for those adjustments.
- Where can I get the ÉCRU decarboxylator manual?
- A printed user manual ships in the box - the Green 2oz also includes a cookbook. If yours is missing or you need it in another format, contact support with your model (ECRU-IF-01 or ECRU-IF-02) and we will send it.
The canister models this page covers
Herb Decarboxylator Green 2oz
2 oz dry / 10 oz liquid · 3 preset heat cycles
$86.99View product2 in 1 Decarboxylator & Infuser 3oz
3 oz dry / 20 oz liquid · Independent Decarb and Infuse modes
$106.99View product
The newer 3 in 1 Herbal Infuser Machine 1L uses a different control panel - eight presets and Delay Start on one display - so its operating guide lives on its product page rather than here.